British Standard Bs 1363 Download Google

• • • AC power plugs and sockets are devices that allow electrically operated equipment to be connected to the primary (AC) in a building. Electrical plugs and sockets differ in and rating, shape, size and type of connectors. The types used in each country are set by national standards, some of which are listed in the technical report TR 60083, Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC. The scope of IEC TR 60083 states: 'The report only contains systems for which standard sheets have been published in a National Standard, which may be a National Standard of the country itself or any other IEC member country'. Plugs and sockets for portable appliances started becoming available in the 1880s, to replace connections to light sockets with easier to use wall-mounted outlets. A proliferation of types developed to address the issues of convenience and protection from electric shock. Today there are approximately 20 types in common use around the world, and many obsolete socket types are still found in older buildings.

British Standard Bs 1363 Download Google

Co-ordination of technical standards has allowed some types of plugs to be used over wide regions to facilitate trade in electrical appliances, and for the convenience of travellers and consumers of imported electrical goods. Some multi-standard sockets allow use of several different types of plugs; improvised or unapproved adaptors between incompatible sockets and plugs may not provide the full safety and performance of an approved socket and plug combination. Plugs and sockets may sometimes combine male and female contacts, but the exposed pins or terminals in the socket are not energized. Clockwise from top left: CEE 7/4 (German) plug and matching CEE 7/3 socket; CEE 7/5 (French) socket.

The publishes IEC 60050, the International Electrotechnical Vocabulary, which is also available as IEV Online. Generally the plug is the movable connector attached to an electrically operated device's, and the socket is fixed on equipment or a building structure and connected to an energised electrical circuit. The plug has protruding pins or, in US terminology, blades (referred to as ) that fit into matching slots or holes (called ) in the sockets. A plug is defined in IEC 60050 as an accessory having pins designed to engage with the contacts of a socket-outlet, also incorporating means for the electrical connection and mechanical retention of flexible cables or cords; a plug does not contain components which modify the electrical output from the electrical input (except where a switch or fuse is provided as a means of disconnecting the output from input). There is an erroneous tendency to refer to power conversion devices with incorporated plug pins as plugs, but IEC 60050 refers to these as 'direct plug-in equipment', defined as equipment in which the mains plug forms an integral part of the equipment enclosure so that the equipment is supported by the mains socket-outlet. In this article, the term 'plug' is used in the sense defined by IEC 60050.

Sockets are designed to prevent exposure of bare energised contacts. Sockets may also have protruding exposed contacts, but these are used exclusively for (earthing). To reduce the risk of users accidentally touching energized conductors and thereby experiencing, plug and socket systems often incorporate safety features in addition to the recessed slots or holes of the energized socket.

UK plugs are always referred as 13 A fused plugs that mostly used in UK, Ireland and former British territories, e.g. Hong Kong, Singapore, Malaysia and Saudi Arabia etc. The National Safety Standard of UK plugs is governed by, or the plugs should be complied with, the British Standard of BS 1363 Part 1 (always quoted as.

These may include plugs with insulated sleeves, recessed sockets, sockets with blocking shutters, and sockets designed to accept only compatible plugs inserted in the correct orientation. The term plug is in general and technical use in all forms of English, common alternatives being power plug, electric plug, and (in the UK) plug top. The normal technical term (in both British and International English) for an AC power socket is socket-outlet, but in non-technical contexts a number of other terms are in common use. In British English the general term is socket, but there are numerous common alternatives, including power point, plug socket, wall socket, and wall plug. In American English receptacle (which is a term not defined in IEC 60050) is used in official standards and codes such as the standard and the. The American 's National Electrical Installation Standards (NECA 130-2010) defines outlet as 'A point on the wiring system at which current is taken to supply utilization equipment.' In common use outlet is used to refer to the actual receptacle or socket, sometimes with qualifiers such as wall outlet, electrical outlet and electrical receptacle, all of these sometimes to be found in the same document.

There is also colloquial use of socket in American English. A socket may be surrounded by a decorative or protective cover called a wall plate, face plate, outlet cover, socket cover, or wall cover. In some designs this is an integral piece with the socket itself, bought and installed as a single unit.

British Standard Bs 1363 Download Google

Electrical sockets for domestic, commercial and light industrial purposes generally provide either two or three electrical connections to the supply conductors. Two-pin sockets normally provide neutral and line connections, both of which carry current and are defined as live parts. Neutral is usually very near to earth potential, usually being earthed either at the distribution board or at the substation. Line (also known as phase or hot, and commonly, but technically incorrectly, as live) carries the full supply voltage relative to the neutral (and to earth). Three-pin sockets provide, in addition, a protective earth connection for exposed metal parts of an appliance. If internal insulation should fail, a short-circuit to the earthed exposed metal parts will hold them at a low potential, and should operate fuses or circuit breakers to isolate the faulty appliance from the supply. Depending on the supply system, some sockets may have two line connections, each at significant voltage to earth and without a neutral pin; for example, a system may have 240 V between line connections each at 120 V with respect to earth ground; but a single-phase receptacle connected to a three-phase system may have, for example, 208 V between contacts and only 120 V between each contact and earth ground.

An adaptor (in the context of plugs and sockets) is defined in IEC 60050 as a portable accessory constructed as an integral unit incorporating both a plug portion and one or more socket-outlet portions. (There is an alternative spelling, adapter, but adaptor is the form usually used in standards and official documents.) History [ ] Early history [ ]. See also: There are two basic standards for voltage and frequency in the world. One is the European standard of 220–240 volts at 50 Hz, and the other is the North American standard of 120 volts at a of 60.

The differences arose for historical reasons as discussed in the article. The plugs and sockets used in each country are set by national standards, some of which are listed in the technical report TR 60083, Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC. The IEC also maintains a Web page giving arbitrary letter designations for generally compatible types of plugs. The IEC Web page does not identify the national standards corresponding to each plug letter. The letter codes are often used as a de facto naming standard when comparing different AC power plugs, especially when describing travel adaptors. Physically identical sockets may be connected to voltages incompatible with an appliance. The letter codes do not identify all the variants of a plug and socket family for different current ratings or for special purposes, and not all plug types have been assigned letters.

Where an IEC letter code exists it is shown in this article. An earlier, and now obsolescent, US government list of letter designations was last revised in 1998, intended as a guide for Americans travelling or working in other countries. In Europe, the (CENELEC) publishes a list of approved plug and socket standards used in the member countries.

Argentina IRAM 2073 and 2071 and compatible types (Type I) [ ] The plug and socket used in Class 1 applications in Argentina is defined. The applicable standards are: IRAM 2073 'Two pole plugs with earthing contact for domestic and similar purposes, rated 10 A and 20 A, 250 V AC' and IRAM 2071 'Two pole socket—outlets with earthing contact for 10 A and 20 A, 250 V AC., for fixed installations.' It is similar in appearance to the Australasian and Chinese plugs. It has an earthing pin and two flat current-carrying pins forming an upside down V-shape (120°). The flat blades for the 10 A version measure 6.25 by 1.55 mm (0.246 by 0.061 in) and 8.0 by 1.9 mm (0.315 by 0.075 in) for the 20 A version, and are set at 30° to the vertical at a nominal pitch of 7.92 mm (0.312 in). The pin length is the same as in the Chinese version. The earthing pin length is 21.4 mm (0.843 in) for the 10 A version and 21.8 mm (0.858 in) for the 20 A version.

The poles plugs length is 18.2 mm (0.717 in) for the 10 A version and 17.8 mm (0.701 in) for the 20 A version. The most important difference from the Australian plug is that the Argentinian plug is wired with the line and neutral contacts reversed. Argentinian 1996 power plug arrangement In Brazil, similar plugs and sockets are still commonly used for high-power appliances like air conditioners, dishwashers, and household ovens. Although being often called 'Argentinian plug,' it is actually based on the American NEMA 10-20 standard, and is incompatible with Argentinian IRAM plugs.

Since Brazil adopted the NBR 14136 standard which includes a 20 A version, the original motivation to use the NEMA 10-20 plug has ceased to exist. [ ] Australasian standard AS/NZS 3112 (Type I) [ ]. Australasian switched 3-pin dual power point (socket) rated 10 amperes The plug used in Australia, New Zealand, Fiji, Tonga, Solomon Islands, and Papua New Guinea has an earthing pin and two flat current-carrying pins forming an upside down V-shape. The flat blades measure 6.5 by 1.6 mm (0.256 by 0.063 in) and are set at 30° to the vertical at a nominal pitch of 13.7 mm (0.539 in). Australian and New Zealand wall sockets, termed General Purpose Outlet (GPO), almost always have switches on them for extra safety, as in the UK. An unearthed version of this plug with two angled power pins but no earthing pin is used with small double-insulated appliances, but the sockets always include an earth contact. There are several AS/NZS 3112 plug variants, including ones with larger or differently shaped pins used for devices drawing 15, 20, 25 and 32.

These sockets accept plugs of equal or of a lower current capacity, but not of higher capacity. For example, a 10 A plug will fit all sockets but a 20 A plug will fit only 20, 25 and 32 A sockets. In New Zealand PDL 940 'Tap-on' or Piggy-back plugs are available which allow a second 10 A plug, or a charger, to be fitted to the rear of the plug. Australia's standard plug/socket system was originally codified as standard C112 (floated provisionally in 1937, and adopted as a formal standard in 1938), which was superseded by in 1990. The requirement for insulated pins was introduced in the 2004 revision.

The current version is AS/NZS 3112:2011, Approval and test specification—Plugs and socket-outlets. Brazilian standard NBR 14136 (Type N) [ ] Brazil, which had been using mostly Europlugs, and NEMA 1–15 and NEMA 5–15 standards, adopted a (non-compliant) variant of as the national standard in 1998 under specification NBR 14136 (revised in 2002). These are used for both 220 volt and 127 volt regions of the country, despite the IEC 60906-2 recommendation that NEMA 5-15 be used for 120 V connections. There are two types of sockets and plugs in NBR 14136: one for 10 A, with a 4.0 mm pin diameter, and another for 20 A, with a 4.8 mm pin diameter. This differs from IEC 60906-1 which specifies a pin diameter of 4.5 mm and a rating of 16 A. NBR 14136 was not enforced in that country until 2007, when its adoption was made optional for manufacturers. It became compulsory on January 1, 2010.

Few private houses in Brazil have an earthed supply, so even if a three-pin socket is present it is not safe to assume that all three terminals are actually connected. Most large domestic appliances were sold with the option to fit a flying earth tail to be locally earthed, but many consumers were unsure how to use this and so didn't connect it. The new standard has an earth pin, which in theory eliminates the need for the flying earth tail.

BS 546 3-pin plugs. Left to right: 15 A, 5 A and 2 A. BS 546, 'Two-pole and earthing-pin plugs, socket-outlets and socket-outlet adaptors for AC (50-60 Hz) circuits up to 250V' describes four sizes of plug rated at 2 A, 5 A (Type D), 15 A (Type M) and 30 A. The plugs have three round pins arranged in a triangle, with the larger top pin being the earthing pin. The plugs are polarized and unfused. Plugs are non-interchangeable between current ratings. Introduced in 1934, the BS 546 type has mostly been displaced in the UK by plugs and sockets to the BS 1363 standard.

According to the IEC some 40 countries use Type D and 15 countries use Type M. Some, such as India and South Africa, use standards based on BS 546.

BS 1363 (Type G) [ ]. Comparison of moulded plugs. Schuko type weighing 47g and BS 1363 weighing 44g, both manufactured by Longwell Company BS 1363 '13 A plugs, socket-outlets, adaptors and connection units' is the main plug and socket type used in the United Kingdom.

According to the it is also used in over 50 countries worldwide. Some of these countries have national standards based on BS 1363, including:,,,, and. This plug, commonly called a 13 A plug or 13 amp plug, has three rectangular pins forming an isosceles triangle.

The BS 1363 plug has a which is suitably rated to protect the appliance's flexible cord from overload. Shaver supply unit for BS 4573, US, Australian and Europlugs. In the United Kingdom, Ireland and Malta, there is a two-pin plug and socket for use with electric shavers and toothbrushes. The plug has insulated sleeves on the pins. The BS 4573 socket is suitable for use in dry areas only, so is rarely used in a stand-alone form.

It is more usual to find shaver supply units meeting BS EN 61558-2-5; these include an and sockets accepting various two-pin plug types including BS 4573, Europlug and Australian and sometimes a 115 V output for two-pin US plugs. (BS EN 61558-2-5 does not define any particular socket.). CEE 7 standards [ ] The International Commission on the Rules for the Approval of Electrical Equipment () was a standards body which published Specification for plugs and socket-outlets for domestic and similar purposes as CEE Publication 7, known simply as CEE 7. It was originally published in 1951, the 2nd edition was published in May 1963 and was last updated by Modification 4 in March 1983.

CEE 7 consists of general specifications, plus a number of standard sheets for specific connectors. A number of standards based on two round pins with centres spaced at 19 mm are in use in continental Europe and elsewhere, most of these are listed in IEC/TR 60083 Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC. There is no regulation of domestic mains plugs and sockets, the specifically excludes domestic plugs and sockets. EU countries each have their own regulations and national standards, for example some require child-resistant shutters, others do not. Is neither applicable nor permitted on plugs and sockets. CEE 7/1 unearthed socket and CEE 7/2 unearthed plug [ ].

CEE 7/4 plug partially inserted in CEE 7/1 non-earthed socket, pins are in contact but exposed. There is no connection for the earthing contact CEE 7/1 unearthed sockets are designed to accept CEE 7/2 round plugs without notches in the body and having 4.8 by 19 mm (0.189 by 0.748 in) pins. Because they have no earth connections they have been or are being phased out in most countries. The regulations of countries using the CEE 7/3 and CEE 7/5 socket standards vary in whether CEE 7/1 sockets are still permitted in environments where the need for earthing is less critical. Sweden, for example, prohibited them from new installations in 1994. In Germany unearthed sockets are rare, whereas in the Netherlands and Sweden it is still common to find them in 'dry areas' such as in bedrooms or living rooms. Some countries prohibit use of unearthed and earthed sockets in the same room, in the 'insulated room' concept, so that people cannot touch an earthed object and one that has become live, at the same time.

The depth of the sockets varies between countries and age. Older sockets are so shallow that it is possible to touch the pins of a plug when the plug is inserted only deep enough to get electrical power on the pins, while newer sockets are deep enough to protect from this kind of accident. CEE 7/1 sockets accept CEE 7/4, CEE 7/6 and CEE 7/7 plugs without providing an earth connection. The earthed CEE 7/3 and CEE 7/5 sockets were specifically designed not to allow insertion of CEE 7/2 unearthed round plugs fitted to older appliances which had to be earthed via other means.

Schuko plug (CEE 7/4) and socket (CEE 7/3) The CEE 7/3 socket and CEE 7/4 plug are commonly called. The socket (which is often, in error, also referred to as CEE 7/4) has a predominantly circular recess which is 17.5 mm (0.689 in) deep with two symmetrical round apertures and two earthing clips on the sides of the socket positioned to ensure that the earth is always engaged before live pin contact is made. The plug pins are 4.8 by 19 mm (0.189 by 0.748 in). The Schuko connection system is symmetrical and unpolarised in its design, allowing line and neutral to be reversed.

The socket also accepts Europlugs and CEE 7/17 plugs. It is rated at 16 A.

The current German standards are -06 'Two-pole plugs with earthing-contact 10 A 250 V≅ and 10 A 250 V–, 16 A 250 V∼' (which also includes CEE 7/7 plug) and DIN 49440-1:2006-01 'Two-pole socket-outlets with earthing contact, 16 A 250 V a.c.' In addition to Germany, it is used in Albania, Austria, Belarus, Bosnia and Herzegovina, Bulgaria, Chile, Croatia, Denmark, Estonia, Finland, Greece, Hungary, Iceland, Indonesia, Iran, Italy (standard CEI 23-50), Kazakhstan, Latvia, Lithuania, Luxembourg, Republic of Macedonia, Republic of Moldova, the Netherlands, Norway, Pakistan, Portugal, Romania, Russia, Serbia, Slovenia, South Korea, Spain, Sweden, Turkey, Ukraine, and Uruguay. Schuko is an abbreviation for the German word Schutzkontakt, which means 'Protective contact' - in this case 'protective' refers to the earth. Some countries, including South Korea, Portugal, Finland, Denmark, Norway and Sweden, require child-proof socket shutters; the German DIN 49440-1:2006-01 standard does not have this requirement.

Rewireable French plug The CEE 7/5 socket and CEE 7/6 plug are defined in French standard NF C 61-314 'Plugs and socket-outlets for household and similar purposes' (which also includes CEE 7/7, 7/16 and 7/17 plugs) The socket has a predominantly circular recess which is 15 mm (0.591 in) deep with two symmetrical round apertures and a round 4.8 mm (0.189 in) earth pin projecting from the socket such that the tip is 23 mm (0.906 in) beyond the live contacts, to ensure that the earth is always engaged before live pin contact is made. The earth pin is centred between the apertures, offset by 10 mm (0.394 in). The plug (which is often, in error, also referred to as CEE 7/5) has two round pins measuring 4.8 by 19 mm (0.189 by 0.748 in), spaced 19 mm (0.748 in) apart and with an aperture for the socket's projecting earth pin. This standard is also used in Belgium, Poland, the Czech Republic, Slovakia and some other countries. Although the plug is polarised, CEE 7 does not define the placement of the line and neutral and there is no universally-observed standard. However, the Czech standard recommends that the line wire to be on the left side when facing the socket.

The French convention changed circa 2002 from nothing particular, to, if the earth pin was at the top then the line hole in the socket would be on the right looking at the socket [ ]. However, the socket may not necessarily be installed with the earth pin at the top. Packaging in France of sockets is normally marked with correct connection of the cables. Polarised pre-fitted plugs on appliances are therefore connected with the brown line wire to the right pin and the blue neutral wire to the left, the earth being connected to the contact at the 'top' of the plug. CEE 7/2 and 7/4 plugs are not compatible with the CEE 7/5 socket because of the round earthing pin permanently mounted in the socket. CEE 7/7 plug To bridge the differences between German and French standards, the CEE 7/7 plug was developed. It is polarised to prevent the line and neutral connections from being reversed when used with a French CEE 7/5 socket, but allows polarity reversal when inserted into a German CEE 7/3 socket.

The plug is rated at 16 A. It has earthing clips on both sides to connect with the CEE 7/3 socket and a female contact to accept the earthing pin of the CEE 7/5 socket.

Currently, appliances in many countries are sold with non-rewireable CEE 7/7 plugs attached, enabling use in all countries whose socket standards are based on either CEE 7/3 or CEE 7/5. CEE 7/16 plugs [ ] The CEE 7/16 standard sheet appears in Supplement 2 (June 1962) to the 1951 edition of CEE 7. The CEE 7/16 unearthed plug is used for low power, it has two round 4 by 19 mm (0.157 by 0.748 in) pins, rated at 2.5 A.

There are two variants. CEE 7/16 Alternative I [ ] Alternative I is a round plug with cutouts to make it compatible with CEE 7/3 and CEE 7/5 sockets. Although it is similar in appearance to CEE 7/17 it has narrower pins (4 mm) and a lower current rating (maximum 2.5 A). This alternative is seldom used. CEE 7/16 Alternative II 'Europlug' (Type C) [ ]. Example of a Europlug Alternative II, popularly known as the, is a flat plug.

It is also defined by Cenelec standard EN 50075 'Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II-equipment for household and similar purposes', which has national equivalents in most European countries, as described in IEC 60083. The Europlug is not rewirable and must be supplied with a flexible cord. Because it is unpolarised, it can be inserted in either direction into a socket, so line and neutral are connected arbitrarily.

Plugs and sockets are usually designed together, with the contacts of the socket part designed to accept the specific pin diameter, pin length, and pin spacing of the mating plug part. However, there is no socket defined by EN 50075; neither is there a socket specified in CEE 7 to accept only 4 mm (0.157 in) pins or the profile of a Europlug.

(There are examples of sockets on the market which accept only such plugs, sometimes in multiples, but these meet no recognized standard.) Instead of being designed with a matching socket, the Europlug was designed to be compatible with a range of sockets in common use throughout mainland Europe. These sockets, including the CEE 7/1, CEE 7/3 (German/'Schuko'), CEE 7/5 (French), and most Israeli, Swiss, Danish and Italian sockets, were designed to accept pins of various diameters, mainly 4.8 mm but also 4.0 mm and 4.5 mm, and are usually fed by final circuits with either 10 A or 16 A overcurrent protection devices. To improve contact with socket parts intended to receive pins having a diameter larger than 4.0 mm, the Europlug has two round, slightly flexible pins which converge slightly towards their free ends. The Europlug is physically not compatible with 13 A sockets, however most modern UK dedicated shaver sockets designed to accept BS 4573 shaver plugs also accept Europlugs for applications requiring less than 200 mA.

Other than such personal hygiene applications, UK consumer protection legislation does not permit the supply of appliances fitted with Europlugs. Apart from use in continental Europe, the Europlug is also used in the Middle East (Iran), most African nations, South America (Argentina, Bolivia, Brazil, Chile, Peru and Uruguay), Asia (India, Bangladesh, Sri Lanka, Indonesia, Pakistan, China, South Korea, Thailand, Philippines, Malaysia and Singapore) as well as Russia and the former Soviet republics, such as Ukraine, Armenia, Georgia, and many developing nations. Where permitted it is also used, by means of adaptors, in many nations, particularly former British colonies, which use the BS 1363 standard. CEE 7/17 plug This is a round plug which conforms to a shape compatible with CEE 7/1, CEE 7/3, and CEE 7/5 sockets. It has two round pins measuring 4.8 by 19 mm (0.189 by 0.748 in).

It may be rated at either 10 A or 16 A, and may be used for unearthed Class II appliances (and in South Korea for all domestic non-earthed appliances). It is also defined as the Class II plug in Italian standard CEI 23-50. It can be inserted into Israeli SI 32 with some difficulty.

The Soviet standard includes both the CEE 7/17 and the CEE 7/16 variant II plug. Socket for the tilted flattened pins and half-round earth pin of Danish computer equipment plug (mainly used in professional environment), standard DK 2-5a This standard plug is described in the Danish Plug Equipment Section 107-2-D1 Standard sheet (SRAF1962/DB 16/87 DN10A-R). Unlike the French CEE 7/6 plug, the earthing pin is on the plug, not in the socket.

The Danish socket need not be recessed to protect the earthing pin. The Danish standard provides for sockets to have child-resistant shutters. The Danish socket will also accept the CEE 7/16 Europlug or CEE 7/17 Schuko-French hybrid plug. CEE 7/4 (Schuko), CEE 7/7 (Schuko-French hybrid), and earthed CEE 7/6 French plugs will also fit into the socket but should not be used for appliances that need earth contact. The current rating on both plugs is 13 A.

A variation (standard DK 2-5a) of the Danish plug is for use only on surge protected computer sockets. It fits into the corresponding computer socket and the normal socket, but normal plugs deliberately don't fit into the special computer socket.

The plug is often used in companies, but rarely in private homes. There is a variation for hospital equipment with a rectangular left pin, which is used for life support equipment.

Traditionally all Danish sockets were equipped with a switch to prevent touching live pins when connecting/disconnecting the plug. Today, sockets without switch are allowed, but then it is a requirement that the sockets have a cavity to prevent touching the live pins. The shape of the plugs generally makes it difficult to touch the pins when connecting/disconnecting. Since the early 1990s earthed sockets have been required in all new electric installations in Denmark.

Older sockets need not be earthed, but all sockets, including old installations, must be protected by (HFI or HPFI in Danish) by 1 July 2008. As of 1 July 2008, wall sockets for French 2-pin, female earth CEE 7/5 are permitted for installations in Denmark. This was done because no electrical equipment sold to private users is equipped with a Danish plug. Sockets for the Schuko were not permitted until 15 November 2011. It could also result in a bad connection of the pins, with resultant risk of overheating and fire. Many international travel adaptor sets sold outside Denmark match CEE 7/16 (Europlug) and CEE 7/7 (Schuko-French hybrid) plugs which can readily be used in Denmark.

Denmark has allowed CEE 7/3 'Schuko' sockets since 15 November 2011. Side by side comparison of Italian CEI 23-50 S 11 and S 17 plugs and sockets rated 16 A (left) and 10 A (right). Italian plugs and sockets are defined by the standard CEI 23-50 which superseded CEI 23-16. This includes models rated at 10 A and 16 A that differ in contact diameter and spacing (see below for details).

Both are symmetrical, allowing the line and neutral contacts to be inserted in either direction. This plug is also commonly used in Chile and Uruguay. 10 A plugs and socket Pins which are 4 mm in diameter, the centres spaced 19 mm apart.

The 10 A three-pin earthed rear entry plug is designated CEI 23-50 S11 (there are also two side-entry versions, SPA 11 and SPB 11). The 10 A two-pin unearthed plug is designated CEI 23-50 S10. The 10 A three-pin earthed socket is designated CEI 23-50 P11, and the 10 A two-pin unearthed socket is designated CEI 23-50 P10. Both 10 A sockets also accept Europlugs.

16 A plug and socket Pins which are 5 mm in diameter, the centres spaced 26 mm apart. The 16 A three-pin earthed rear entry plug is designated CEI 23-50 S17 (there are also two side-entry versions, SPA 17 and SPB 17). The 16 A two-pin unearthed plug is designated CEI 23-50 S16.

The 16 A three-pin earthed socket is designated CEI 23-50 P17, there is not a 16 A two-pin unearthed socket. The 16 A socket used to be referred to as per la forza motrice (for electromotive force, see above) or sometimes (inappropriately) industriale (industrial). Old adaptor from forza to 2 × luce and 1 × forza The two standards were initially adopted because up to the second half of the 20th century in many regions of Italy electricity was supplied by means of two separate consumer connections — one for powering illumination and one for other purposes — and these generally operated at different voltages, typically 127 V single phase and 220 V single or split phase.

The electricity on the two supplies was separately metered, was sold at different tariffs, was taxed differently and was supplied through separate and different sockets. Even though the two electric lines (and respective tariffs) were gradually unified beginning in the 1960s (the official, but purely theoretical date was the summer of 1974) many houses had dual wiring and two electricity meters for years thereafter; in some zones of Lazio the 127 V network was provided for lighting until 1999. The two gauges for plugs and sockets thus became a which is now formalized under CEI 23-50. Some older installations have sockets that are limited to either the 10 A or the 16 A style plug, requiring the use of an adaptor if the other gauge needs to be connected. Numerous cross adaptors were used. Appliances with CEE 7/7 (German/French) plugs are often sold in Italy, but the standard sockets will not always accept them since the pins of the CEE 7/7 plugs are thicker (4.8 mm) than the Italian ones (4 mm).

Adaptors are standardized in Italy under CEI 23-57 which can be used to connect CEE 7/7 plugs to linear CEI 23-50 sockets. Europlugs are also in common use in Italy; they are standardized under CEI 23-34 S 1 for use with the 10 A socket and can be found fitted to Class II appliances with low current requirement (less than 2.5 A). The current Italian standards provide for sockets to have child-resistant shutters ('Sicury' patent).

Italian multiple standard sockets [ ]. In modern installations in Italy (and in other countries where Type L plugs are used) it is usual to find sockets that can accept more than one standard. The simplest type, designated CEI 23-50 P17, has a central round hole flanked by two figure-8 shaped holes, allowing the insertion of both 10 A and 16 A Italian plugs and the Europlug. The advantage of this socket style is its small, compact face.

Vimar brand claims to have patented this socket first in 1975 with their Bpresa model; however soon other brands started selling similar products, mostly naming them with the generic term presa bipasso (twin-gauge socket) that is now of common use. A second, quite common type looks like a Schuko socket, but adds a central earthing hole. This design can accept CEE 7/4 (German), CEE 7/7 (German/French), and Italian 10 A plugs. Some of these sockets may also have figure-8 shaped holes to accept Italian 16 A plugs as well. Its drawback is that it is twice as large as a normal Italian socket and the price is higher; for those reasons Schuko and bipasso-Schuko socket have been rarely installed in Italy until recent times.

[ ] Other types may push compatibility even further. The Vimar-brand universale (all purpose) socket, for example, accepts CEE 7/4 (German), CEE 7/7 (German/French), Italian 10 and 16 A plugs, and also NEMA 1-15 (US/Japan) plugs (older versions also had extra holes to accept UK shaver plugs). For more details on this topic, see.

This Soviet plug, still widely used in modern Russia, has pin dimensions and spacing equal to the Europlug, but lacks the insulation sleeves. Unlike the Europlug, it is rated 6 A.

It has a round body like the French CEE 7/6 or flat body with a round base like CEE 7/17. The round base has no notches. The pins are parallel and do not converge. The body is made of fire resistant. The corresponding 6 A socket accepts the Europlug, but not others as the 4.5 mm holes are too small to accept the 4.8 mm pins of CEE 7/4, CEE 7/6 or CEE 7/7 plugs. There were also moulded rubber plugs available for devices up to 16 A similar to CEE 7/17, but with a round base without any notches. They could be altered to fit a CEE 7/5 or CEE 7/3 socket by cutting notches with a sharp knife.

SEV 1011:2009, overview of the hierarchical Swiss System The three phase variants of the standard are also described. All of the single phase connectors are rated at 250 V. The three-phase connectors are rated at 250 V (phase-to-neutral) / 400 V (phase-to-phase). The Swiss standard does not require the use of child protective shutters. 10 A plugs and sockets (Type J) [ ] SEV 1011 defines a 'Type 1x' series of 10 A plugs and sockets. The type 11 plug is unearthed, with two 4 mm diameter round pins spaced 19 mm apart. The type 12 plug adds a central 4 mm diameter round earth pin, offset by 5 mm.

The type 12 socket has no recess, while the type 13 socket is recessed. Both sockets will accept type 11 and type 12 plugs, and also the 2.5 A. From 2017 only recessed sockets are permitted to be installed, minimizing the risk of electric shocks. Earlier type 11 & 12 plugs had line and neutral pins without sleeved pins, which present a hazard when partially inserted into non-recessed sockets.

Since 1 January 2013, only type 11 & 12 plugs with line and neutral pins partially sleeved are allowed to be imported and distributed to reduce the risk. The IEC type J designation refers to SEV 1011's type 12 plugs and type 13 sockets. Unique to Switzerland is a three-phase power socket compatible with single-phase plugs: The type 15 plug has three round pins, of the same dimensions as type 12, plus two smaller flat rectangular pins for two additional power phases.

The type 15 socket is recessed, and has five openings (three round and two flat rectangular). It will accept plugs of types 11, 12, 15 and the Europlug. 16 A plugs and sockets [ ] SEV 1011 also defines a 'Type 2x' series of 16 A plugs and sockets. These are the same as their 10 A 'Type 1x' counterparts, but replace the round pins with 4 mm × 5 mm rectangular pins. The sockets will accept 'Type 1x' plugs.

The unearthed type 21 plug has two rectangular pins, with centres 19 mm apart. The type 23 plug adds a central rectangular earth pin, offset by 5 mm. The recessed type 23 socket will accept plugs of types 11, 12, 21, 23 and the Europlug. Again, the three-phase power socket is compatible with single-phase plugs, either of 10 A or 16 A ratings: The type 25 plug has three rectangular pins of the same dimensions as type 23, plus two rectangular pins of the same dimensions as type 15.

The corresponding type 25 socket is recessed and will accept plugs of types 11, 12, 15, 21, 23, 25 and the Europlug. Adaptors etc.

[ ] A 2012 appendix to SEV 1011:2009, SN SEV 1011:2009/A1:2012 Plugs and socket-outlets for household and similar purposes - A1: Multiway and intermediate adaptors, cord sets, cord extension sets, travel adaptors and fixed adaptors defines the requirements applicable to multiway and intermediate adaptors, cord sets, cord extension sets, and travel and fixed adaptors, it covers the electrical safety and user requirements, including the prohibition of stacking (the connection of one adaptor to another). Non-conforming products must be withdrawn from the Swiss market before the end of 2018. For more details on this topic, see.

In 1986, the International Electrotechnical Commission published IEC 60906-1, a specification for a plug and socket that look similar, but are not identical, to the Swiss plug and socket. This standard was intended to one day become common for all of Europe and other regions with 230 V mains, but the effort to adopt it as a European Union standard was put on hold in the mid-1990s. The plug and socket are rated 16 A 250 V a.c. And are intended for use only on systems having nominal voltages between 200 V and 250 V a.c. The plug pins are 4.5 mm in diameter, line and neutral are on centres 19 mm apart.

The earth pin is offset 3.0 mm. The line pin is on the left when looking at a receptacle with the earth pin offset down. Shutters over the line and neutral pins are mandatory. The only country to have officially adopted the standard is South Africa as SANS 164-2.

Brazil developed a plug resembling IEC 60906-1 as the national standard under specification NBR 14136. The NBR 14136 standard has two versions, neither of which has pin dimensions or ratings complying to IEC 60906-1. Use at 125 V is permitted by NBR 14136, which is against the intention of IEC 60906-1. China CPCS-CCC (Type I) [ ]. Chinese 3-pin socket and compound socket which also accepts NEMA and Europlug (right), and a less common 16 A version (left) The standard for Chinese plugs and sockets (excluding Hong Kong and Macau) is set out in 2099.1‐2008 and GB 1002‐2008. As part of China's commitment for entry into the, the new CPCS (Compulsory Product Certification System) has been introduced, and compliant Chinese plugs have been awarded the by this system.

The plug is three wire, earthed, rated at 10 A, 250 V and used for Class 1 applications; a slightly larger 16 A version also exists. The nominal pin dimensions of the 10 A version are: 1.5 mm thick by 6.4 mm wide, the line & neutral are 18 mm long, and the earth is 21 mm long. It is similar to the Australian plug.

Many 3 pin sockets in China include a physical lockout preventing access to the active and neutral terminals unless an earth pin (which is slightly longer than the other 2 pins) is entered first. China also uses American/Japanese NEMA 1‐15 sockets and plugs for Class-II appliances. The voltage at a Chinese socket of any type is 220 V. Socket polarity, with wire color coding. The plug defined in () is used only in Israel and in the territories of the and the.

There are two versions: an older one with flat pins, and a newer one with round pins. The pre-1989 system has three flat pins in a Y-shape, with line and neutral 19 mm (0.75 in) apart.

The plug is rated at 16 A. In 1989 the standard was revised, with three round 4.5 mm (0.177 in) pins in the same locations designed to allow the socket to accept both older and newer Israeli plugs, and also non-earthed Europlugs (often used in Israel for equipment which does not need to be earthed and does not use more current than the Europlug is rated for). Pre-1989 sockets which accept only old-style plugs have become very rare in Israel. SI 32 plugs have no sleeve insulation, so when a plug is partially removed its prongs may still be powered although they can be touched by small fingers, metal objects, etc., with a risk of electric shock. Sockets have a defined polarity; looking at the front, neutral is to the left, earth at the bottom, and line to the right. See also: Most of North America and Central America, and some of South America, use connectors standardized by the.

The devices are named using the format NEMA n-mmX, where n is an identifier for the configuration of pins and blades, mm is the maximum amperage, and X is either P for plug or R for receptacle. For example, NEMA 5-15R is a configuration type 5 receptacle supporting 15 amps.

Corresponding P and R versions are designed to be mated. The prefix, L, is added for the locking types; a 15 A 120 V two-pole grounding plug is designated NEMA L5-15P. Twist-locking types are used for additional protection from accidental disconnection, or to prevent interchange with parallel blade types For some configurations, the arrangement of pins will differ slightly for the different current ratings, to prevent accidental mating of devices with a higher current draw than the receptacle can support. IEC 60906-2 is based on NEMA 5-15.

A brief description of some common NEMA standards appears below. A more comprehensive list, with more detail, appears in the article.

NEMA 1-15 ungrounded (Type A) [ ]. Main article: NEMA-1 plugs, rated 15 A at 125 volts, are compatible with both NEMA-1 receptacles and NEMA-5 receptacles; NEMA-1 is ungrounded (no earth), while NEMA 5 is grounded. The plug has two parallel blades.

Early versions were not polarized, but most plugs are polarized today via a wider neutral blade on the plug that fits a wider neutral opening on the receptacle. (Unpolarized are a common exception.) Harvey Hubbell patented a parallel blade plug in 1913, where the blades were equal width (US Pat.1064833 ). In 1916 Hubbell received a further patent for a polarized version where one blade was both longer and wider than the other (US Pat. 1180648 ), in the polarized version of NEMA 1-15 both blades are the same length, only the width varies. Ungrounded NEMA-1 outlets are not permitted in new building construction in the and, but can still be commonly found in older construction. Allowed replacement of NEMA-1 receptacles varies by local code.

NEMA 5-15 grounded (Type B) [ ]. Main article: The NEMA 5-15 plug has two flat parallel blades like NEMA 1-15, but also adds a ground (earth) pin. It is rated 15 A at 125 volts. The ground (earth) pin is longer than the line and neutral blades, so the device is grounded before the power is connected. Both current-carrying blades on grounding plugs are normally narrow, since the ground (earth) pin enforces polarity. NEMA 1-15 plugs are also compatible with NEMA 5-15 sockets.

The 5-15 socket is standard in Canada, the United States, Mexico and Panama. It is also used in Central America, the Caribbean, northern South America (Colombia, Ecuador, Venezuela and, as a legacy, parts of Brazil), Japan, Taiwan, the Philippines and.

This socket is recommended in IEC standard 60906-2 for 120 volt 60 Hz installations. Looking directly at a NEMA 5-15 socket in the commonly found orientation of ground (earth) at the bottom, the neutral slot is on the left, and the line slot is on the right. However, in the US the National Electrical Installation Standards (NECA 130-2010) specifies that the ground hole should be on top. Sideways installation is also permitted; in this case, NECA 130-2010 specifies the neutral (long) slot is on top. In 46 of the 50 United States and all of Canada, tamper-resistant sockets are now required in new residential construction.

These prevent contact by objects like keys or paper clips inserted into the socket. In, this connector is sometimes known as PBG for Parallel Blade with Ground (earth), Edison or Hubbell, the name of a common manufacturer. NEMA 5-20 [ ]. 5-20RA (Canada) or 5-20R (USA) T-slot socket mounted with the earth hole up.

The neutral connection is the wider T-shaped slot on the right. As NEMA 5 currents increase, changes are made to the plug's neutral blade so that it will not fit into sockets rated for a lower current. Some sockets rated for higher currents are designed to accept many shapes for the neutral blade, so that both high and low draw devices are compatible with it.

The NEMA 5-20 AP variant has a horizontal neutral blade (in a plane that would intersect the hot blade). The receptacle has a T-slot for the neutral blade which accepts either 15 A parallel-blade plugs or 20 A plugs. NEMA 5-30 and 5-50 are rare; L5-30 and L5-50 twistlock is more common.

The non-locking versions are physically incompatible with 5-15 and 5-20, as the hot/neutral blades are farther apart. NEMA 14-30 [ ] A 30 A, 4-wire single-phase grounding socket is often used for electric clothes dryers. 240 volts from the system is used for the heating elements, and the motor and controls run on 120 volts.

These plugs have blades that are rather larger than NEMA 5-20, are more widely spaced, and are angled so as to prevent using the wrong plug in the wrong circuit. These plugs have L-shaped neutral blades that will not fit in a NEMA 14-50 receptacle.

NEMA 14-50 [ ] This is a 50 A, 4-wire grounding socket usually installed in kitchens and used for electric cooking ranges and ovens supplied with 240 V by the system. Similar to dryers on 14-30 sockets, these usually have lights, fans, timers, etc., that are run from 120 V (obtained from one of the 120 legs to neutral). Many plug-in electric cars also use this type of socket for recharging in the owner's garage (but in this case neutral is not needed). It is also commonly found in to provide electricity to recreational vehicles.

These plugs have a straight neutral blade that will not fit in a NEMA 14-30 receptacle. JIS C 8303, Class II unearthed [ ]. Japanese 200V socket with earth post, for an air conditioner The Japanese plug and socket appear physically identical to NEMA 1-15.

The Japanese system incorporates stricter dimensional requirements for the plug housing, different marking requirements, and mandatory testing and approval. Older Japanese sockets and multi-plug adaptors are unpolarized—the slots in the sockets are the same size—and will accept only unpolarized plugs. Japanese plugs generally fit into most North American sockets without modification, but polarized North American plugs may require adaptors or replacement non-polarized plugs to connect to older Japanese sockets. In Japan the voltage is 100 V, and the frequency is either 50 Hz (East Japan) or 60 Hz (West Japan) depending on whether the customer is located on the Osaka or Tokyo grid. Therefore, some North American devices which can be physically plugged into Japanese sockets may not function properly. JIS C 8303, Class I earthed [ ] Japan also uses a grounded plug similar to the North American NEMA 5-15. However, it is less common than its NEMA 1-15 equivalent.

Since 2005, new Japanese homes are required to have class I grounded sockets for connecting domestic appliances. This rule does not apply for sockets not intended to be used for domestic appliances, but it is strongly advised to have class I sockets throughout the home.

TIS 166-2549 plug Thai Industrial Standard (TIS) 166-2547 and its subsequent update TIS 166-2549 replaced prior standards which were based on NEMA 1-15 and 5-15, as Thailand uses 220 V electricity. The plug has two round power pins 4.8 mm in diameter and 19 mm in length, insulated for 10 mm and spaced 19 mm apart, with an earthing pin of the same diameter and 21.4 mm in length, located 11.89 mm from the line connecting the two power pins. The earth pin spacing corresponds to that of NEMA 5 and provides compatibility with prior hybrid three-pin sockets, which accept NEMA 1-15, NEMA 5-15 and Europlugs, all of which have been variably used in Thailand. The hybrid socket is also defined in TIS 166-2547, in addition to a plain three-round-pin socket, with plans to replace the former and phase out support for NEMA-compatible plugs. Sockets are polarised (as in NEMA 5-15). The plug is similar to, but not interchangeable with, the Israeli SI32 plug. The Thai plug has not been designated with a letter code at IEC World Plugs.

• ^ Type letters are from the International Electrotechnical Commission () Web site that provides classification letters similar to a United States Department of Commerce publication that sees widespread but not universal use to differentiate plug and socket types based on rough mechanical compatibility. Most common household plugs have an associated letter. • ^ Will accept unearthed plugs.

• There are some CEE 7/17 plugs with special shape which are polarised when used with CEE 7/5 sockets (mechanically only). • CEE 7/1 socket accepts earthed CEE 7/3, CEE 7/5 and CEE 7/7 plugs but provides no earth connection. • BS 4573 and BS EN 61558-2-5 do not explicitly specify a current rating for a compliant plug, see BS 4573 section of British and compatible standards. • ^ CEE 7/7 specifies an earthed hybrid plug that will fit into both the CEE 7/3 and CEE 7/5 sockets. CEE 7/17 specifies an unearthed hybrid plug that will fit into both the CEE 7/3 and CEE 7/5 sockets. • Plug can only be inserted one way with French CEE 7/5, but lack of wiring convention means that the system is not polarized.

• ^ The recess provided by CEE 7/3 and CEE 7/5 sockets offers protection against touching the live pins of CEE 7/4, CEE 7/6 and CEE 7/7 plugs. When used in CEE 7/1 (unearthed) sockets, or 'universal adaptors' there is no protection for those plugs.

• The actual rating of non-rewirable plugs is marked according to the fuse fitted by the cord set manufacturer, the fuse rating being determined by the rating of the flexible cable. • Polarized on earthed versions only.

• Import of plugs with non-partially-insulated pins no longer allowed after 2012. • ^ Type L comes in two variations with ratings of 10 A & 16 A having different pin diameters and spacing from each other. Multi-standard sockets [ ]. A second type of multi socket that accepts British plugs in addition to Euro, NEMA American and Australian plugs. Sockets that take a variety of plug types can be found in places where market size or local market conditions make a specific plug standard impractical to implement. Sockets may accept plugs to various European, Asian, North American, British or Australian standards, but not Indian or South African.

Multi-standard sockets do not safeguard against devices being damaged by the wrong voltage. Users must know the voltage requirements of their appliances as well as the prevailing local voltage. In some multi-standard sockets the aperture size for NEMA plugs is the same for both Line (Hot) and Neutral (see second picture), which may defeat the polarization of NEMA 1 plugs.

In a socket designed to accept both NEMA and BS 1363 plugs, the lower right contact (in the orientation shown in the picture) should be connected to the Line wire for BS 1363 plugs, but the Neutral wire for NEMA plugs, so safe wiring of these devices for universal use is not possible. Some of these sockets have one or more earth holes to allow 3-pin plugs. On properly wired circuits, the earth contact will be connected to earth. However, they cannot provide earthing to all types of plugs, as is the case of Schuko (which requires recessed sockets containing side earthing contacts) and French plugs (which require an earthing pin projecting from the socket).

Those designed to accept British plugs have pin apertures which are larger than allowed by BS 1363, and are therefore not legal for UK or Irish use. The of the specifically excludes domestic plugs and sockets and is neither applicable nor permitted on plugs and sockets. However, CE marking is sometimes fraudulently used on universal sockets. Leviton NEMA 5-15R duplex receptacle with integrated USB sockets. AC sockets of most types are now available with integrated USB power supplies.

These are normally arranged so that they are the same size as the regular AC sockets of their type, but have one or two USB sockets installed in parts of the faceplate which would otherwise be unoccupied. They are intended to provide a convenient solution for devices requiring DC power or charging via a USB connector, such as cell phones and tablet computers. Adaptors [ ]. 15 A version of BS 546 travel adaptor allow travelers to use portable devices with foreign sockets. Adaptors allow physical connection between plug and socket but do not change voltage or frequency.

A is required for electrical compatibility in countries with a different voltage than the device is designed for, if it is not designed for variable voltage input. Multisocket adaptors allow the connection of two or more plugs to a simple socket. They are manufactured in various configurations, depending on the country and the region in which they are used, with various ratings. In Europe for example, they are called double or triple adaptors, and transform a one socket into a multiple socket. This has the advantage of connecting more than one electrical consumer item to one single socket and is mainly used for low power devices (TV sets, table lamps, computers, etc.). They are usually rated at 6 A 250 V, 10 A 250 V, or 16 A 250 V, however this is the general rating of the adaptor (for example, if we have an adaptor for four sockets and it is marked 16 A 250 V, this means that the adaptor should not be loaded more than 16 A, whether one, two, three or all sockets are used.

Some people overload them, thus leading to accidents). In some countries these adaptors are banned and are not available in shops, as they may lead to fires due to overloading them. In the past, these adaptors were made from ceramic, Bakelite or other fire resistant plastics, but nowadays they are made from various available plastics that can be safely used in electrical devices (such as PA6, PVC, PP). [ ] Some low quality adaptors are made from plastics not approved for electrical use (such as PS or non fire resistant ABS), and these may cause fires in the case of overheating due to overloading or bad contacts.

[ ] Obsolete types [ ] Old Spanish sockets [ ]. Left: Spanish three-pin plug (Eunea 3023-B/Metropoli) and socket (Eunea 3013-B) with removable fuse. Right: adaptor for CEE 7/17 and CEE 7/4 plugs. Some older industrial buildings in Spain used sockets that took a plug rated for higher current and had two flat contacts and a round earth pin, somewhat similar in design to the ones found on American plugs but larger in size. The two flat contacts are spaced further apart than on an American plug. No domestic appliances were ever sold with these plugs. The line and neutral measure 9 by 2 mm (0.354 by 0.079 in), and are 30 mm (1.181 in) apart.

All three pins are 19 mm (0.748 in) long, and the earth pin is a cylinder of 4.8 mm (0.189 in) diameter. Obsolete 125 V, 15 A / 250 V, 10 A duplex outlet A patent for this obsolete American plug and socket was filed in 1915 under US patent 1,179,728.

It predated the NEMA sockets and plugs. The plugs and sockets used in countries such as Argentina, Australia and China are based on this type and are physically compatible. Split current/voltage ratings [ ] Many older North American sockets have two different current and voltage ratings, most commonly 10 A 250 V/15 A 125 V. This has to do with a peculiarity of the National Electrical Code from 1923 to the 1950s. Originally, sockets were rated at 10 A 250 V, because the NEC limited lighting circuits to 10 A. In 1923, the code changed to allow lighting circuits to be fused at 15 A, but the previous 10 A rule still applied to circuits over 125 V.

The higher voltages were rarely used for lighting and appliances. Most sockets with this rating are of the 'T-slot' type.

US perpendicular socket [ ]. Perpendicular slot RP-2B socket 10 A 42 V AC Another obsolete socket, made by Bryant, 125 V 15 A and 250 V 10 A rating. A 5‐20 125 V 20 A or 6‐20 250 V 20 A plug with a missing earth pin would fit this socket, but a NEMA 2‐20 plug is slightly too big to fit. The upper slots as seen in the illustration connect to silver-colored wiring screws on the upper side, and the lower slots connect to brass-coloured wiring screws on the lower side. In Australia, the same or similar T-configuration sockets are used for, such as in (SAPS), on boats and in police vehicles. Polarity is inconsistent.

In the former Soviet Union this socket was and still is commonly used for wiring in places where the voltage is lowered for safety purposes, like in schools, filling stations or in wet areas, and is rated 42 V 10 A AC. Such an unusual connection is intended specifically to make the connection of standard higher-voltage equipment impossible. Left: old 'Nurpolian'-brand black parallel and tandem duplex socket rated at 250 V 10 A (although normally supplied with 120 V). Right: T-slot duplex socket. The parallel and tandem socket accepts normal parallel 1‐15 plugs and also tandem NEMA 2‐15 plugs. Both pairs of sockets are fed internally by the same supply.

A more recent and fairly common version of this type is the T-slot socket, in which the locations of the tandem and the parallel slots were combined to create T-shaped slots. This version also accepts normal parallel NEMA 1‐15 plugs and also tandem NEMA 2‐15 plugs.

Incidentally, a NEMA 5‐20, NEMA 6-15, or NEMA 6‐20 plug with a missing earth pin would fit this socket. This receptacle type has been unavailable in retail shops since the 1960s but still available from the manufacturer Leviton (model 5000-I) for replacement only and not for new installations. Harvey Hubbell had patented the parallel blade plug in 1913, and patented a polarized version in 1916. He also patented the T-slot single outlet in 1915, and a duplex T-slot outlet in 1916 both meant to take his older 1904 tandem and newer parallel plug design. (Single: US Pat.

1146938; Duplex: US Pat. Prior to the 1930s, when Hubbell's parallel blade plug received its official rating of 125v (and became the United States' general service electrical plug standard), all of his electrical connectors were used interchangeably on either 120v or 240v. The two blade tandem configuration plug received its official rating of 250v in the 1950s but has been 'banned' from use since the 1960s because of its lack of a ground or neutral. Note: See the NEMA 1-15 ungrounded (Type A) section of this page for the parallel blade patent reference numbers. Greek old earthed standard adaptor plugs and socket Called 'Tripoliki' (τριπολική, meaning 'three-pole'), the standard had 3 round pins, similar to the post-1989 Israeli SI 32 and Thai TIS 166-2549 types. The Tripoliki was virtually abandoned by the decade of 1980, but can still be found in houses constructed before 1980, and not renovated. Previous to the large-scale adoption of Schuko plugs, this was the only way to use an earthed appliance in Greece.

It can accept Europlugs, and also (but with no earth connection possible) French and German types. Unusual types [ ] Lampholder plug [ ]. Italian bypass lampholder plugs with Edison screw mount.

Left: early type (porcelain and brass, c. 1930); right: late type (black plastic, c. 1970) A lampholder plug fits into the or socket of a lampholder in place of a and enables an electrical appliance to be powered from a wall or ceiling light fitting. As mentioned in Early History above, they were first introduced in the late 1800s and in use to the 1960s in situations where wall sockets were scarce and sometimes non-existent in some rooms (bathrooms, cellars, attics, etc.). Also, as in some countries (such as Italy) electricity was supplied on a 'split tariff' basis with electricity for lighting being charged at a lower rate than that for other purposes, lampholder plugs enabled the consumers to reduce their electricity costs and were thus in broad use.

Lampholder plugs were and are rarely fused. In the UK, lighting circuits are protected with a 5 A fuse or 6 A. Wiring regulations in the UK and some other countries no longer approve lampholder plugs because of the risks of overheating and fire. Edison screw lampholder adaptors (for NEMA 1-15 plugs) are still easily found and commonly used in the Americas.

Main article: These unearthed plugs with two flat parallel blades are intended for use on 240 volt circuits. The 2‐15 has coplanar current blades, and is used for 240 V service at 15 A, while the 2‐20 has the blades at 90° relative to each other (one vertical, one horizontal) and is used for 240 V service at 20 A. NEMA 2 plugs and sockets are rare because they are unearthed and so, no longer permitted for new installations. They have no neutral. In some cases these plugs can be inserted into incorrect-voltage sockets. Prior to the adoption of the NEMA standard, a plug nearly identical to the 2‐20 was used for 120 V at 20 A.

That obsolete plug would fit into 5‐20 and 6‐20 sockets, which supply different voltages, but will not fit a NEMA 2‐20 socket. Soviet adaptor plugs [ ]. Soviet adaptor plug Some appliances sold in the Soviet Union had a flat unearthed plug with an additional pass-through socket on the top, allowing a stacked arrangement of plugs.

This design was very useful, because the usual Soviet apartment of the 1960s had very few sockets, but somewhat unsafe; the brass cylinders of the secondary socket were uncovered at the ends (to allow them to be unscrewed easily), recessed by only 3 mm, and provided bad contact because they relied on the secondary plug's bisected expanding pins. The pins of the secondary plug (which lacked insulation sleeves) could not be inserted into the cylindrical sockets completely, leaving a 5 mm gap between the primary and secondary plugs. The adaptors were mostly used for low power appliances (for example, connecting both a table lamp and a radio to a socket). Walsall Gauge 13 A plug (bottom) compared to regular BS 1363 plug Unlike the standard BS 1363 plugs found in the UK, the earth pin is on a horizontal axis and the line and neutral pins on a vertical axis. This style of plug/socket was used by university laboratories (from batteries) and the, and is still in use on parts of the for 110 V AC voltage supply. In the 1960s they were used for 240 V DC in the Power laboratory of the Electrical Engineering department of what was then University College, Cardiff. Power was supplied by the public 240 V DC mains which remained available in addition to the 240 V AC mains until circa 1969, and thereafter from in-house rectifiers.

They were also used in the on circuits powered from the standby generators to stop staff from plugging in unauthorised devices, e.g. [ ] They were also known to be used in some British Rail offices for the same reason. Italian BTicino brand Magic security connector [ ]. Left: Bticino Magic Security socket, detail.

Centre: assortment of Magic Security sockets (in orange, the industrial three-phase type). Right: assortment of Magic Security plugs.

This style of connector, produced by Italian manufacturer BTicino, appeared in the 1960s and was intended as an alternative to the Europlug or CEI 23-16 connectors then in use. The socket is an almost rectangular socket, with one or more lateral key pins and indentations to prevent inverting the polarised plug, or connecting plugs and sockets with different current ratings. At least four models were produced: three single-phase general purpose connectors rated respectively 10 A, 16 A and 20 A; plus a three-phase industrial connector rated 10 A; all of them have different key-pin positioning so plugs and sockets cannot be mismatched. The socket is closed by a safety lid (bearing the word ‘’Magic’’ on it) which can be opened only with an even pressure on its surface, thus preventing the insertion of objects (except the plug itself) inside the socket. The contacts are blades positioned on both sides of the plug; the plug is energized only when it is inserted fully into the socket. Kudiye Ni Tere Brown Rang De Mp3 Song Download. On the left a BTicino Magic Security plug (10 A), on the right a type L to Magic Security plug adaptor The obvious drawback of the system is that it is not compatible with Europlugs.

As household appliances were never sold fitted with these security plugs and the use of adaptors would defeat all of the newly introduced safety features, once this system is adopted all standard plugs must be cut off and replaced with the appropriate security connector. However, the Magic security system had some success at first because its enhanced safety features appealed to customers; standard connectors of the day were considered not safe enough. The decline of the system occurred when safety lids similar to the Magic type were developed (VIMAR Sicury ) and then applied to standard sockets by third brands and by BTicino itself. In Italy, the system was never definitively abandoned and, though rarely seen today, is still marked as available in BTicino’s products catalogue, (except for the three-phase version, that is no longer in production from July 2011) In Chile, 10 A Magic connectors are commonly used for computer/laboratory power networks, as well as for communications or data equipment.

This allows delicate electronics equipment to be connected to an independent circuit breaker, usually including a or an backup. The different style of plug makes it more difficult for office workers to connect computer equipment to a standard unprotected power line, or to overload the UPS by connecting other office appliances. In Iceland, Magic plugs were widely used in homes and businesses alongside Europlug and Schuko installations. Their installation in new homes was still quite common even in the late 1980s.

Russian stove connectors rated 250 V 25 A AC. Left: plug and socket. Center: Socket. The plugs and sockets used to power from a single-phase line have to be rated for greater current values than ones for three-phase system because all the power has to be transferred through a single line. Electric stoves are often hardwired to the electrical supply system, connected to the mains with an appropriate high power industrial connector or with non-standard high power proprietary domestic connector (as some countries do not have wiring regulations for single-phase electric stoves).

In Russia an electric stove can often be seen connected with a 25 to 32 A connector. In Norway and parts of Sweden a 25 A grounded connector, rectangular shaped with rounded corners, is used for single phase stoves. The connector has three rectangular pins in a row, with the grounding pin longer than other two. The corresponding socket is recessed to prevent shocks. The Norwegian standard is NEK 502:2005 - standard sheet X (socket) and sheet XI (plug).

They are also known as the two pole and earth variants of CEE 7/10 (socket) and CEE 7/11 (plug). Main article: Plug and socket systems intended for high current, high voltage or industrial equipment, as well as additional contacts and larger contacts, may also include features to improve the security and safety of use. For example, a high-power plug may include a locking ring or twist-lock feature to prevent accidental disconnection in use. A socket may include a mechanical interlock that prevents insertion or removal of a plug unless the local safety disconnecting switch is open. Plugs may include special measures to contain an arc generated during disconnection.

Plugs used for equipment in wet locations (such as mines) may include small supervisory contacts that check the integrity of the earthing conductor.

This article examines why it is not possible to plug a British plug directly into a Dutch power socket. The author traces the development of the British Standard BS1363 plug-socket assembly and compares it to the European arrangement in order to demonstrate how the ‘banal nationalism’ of everyday life is formed and can be seen to be manifest in everyday utilitarian artefacts. A concept of nationhood that is formed in terms of ‘national habitus’ is elaborated, the nation is envisaged as being constituted by the socio-technological infrastructures upon which it depends, which are established as being formed by the governmentalities that have allowed them to come into being, and it is suggested that such a system will operate at a range of scales or valencies. By tracing the history of the two examples given, the intention is to demonstrate how each national habitus depends upon a particular technical development shaped by social forces. Billig, M ( 1995) Banal Nationalism. London: Sage. Blalock, T ( 2013) The Rotary Era, Part 1 – Early AC-to-DC Power Conversion, IEEE Power and Energy Magazine, September/October.

Bos, F ( 2010) CPB Document 214; Fiscal Decentralisation in the Netherlands: History, current practice and economic theory. The Hague: CPB Netherlands Bureau for Economic Policy Analysis. Bourdieu, P ( 1987) Distinctions: A Social Critique of the Judgement of Taste. Boston, MA: Harvard University Press. Bozell, H ( 1924) Electrical World, 26 July: 161– 167. Brian, A ( 1989) Competing technologies, increasing returns, and lock-in by historical events. Economic Journal 99: 116– 131., Buiter, H ( 1997) The History of the Power Cables in the Netherlands.

Eindhoven: Stichting Historie der Techniek. Carr, N ( 2009) The Big Switch: Rewiring the World, from Edison to Google.

New York: Norton. Centraal Verslag der Arbeidsinspectie in het Koninkrijk der Nederlanden over 1917–1918 ( 1918). Amsterdam: GJ Thieme. Cochrane, R ( 1985) Power to the People: The Story of the National Grid. London: Hamlyn in association with the Central Electricity Generating Board.

Coles, M ( 2012) Socket protectors. IET Wiring Matters, Autumn. De Rijk, T ( 2009) Pioneers and barbarians: The design and marketing of electrical household goods as Dutch Americana, 1930–45. Journal of Design History 22(2): 115– 132., Dean, M ( 2007) Governing Societies (Issues in Society). Maidenhead: Open University Press.

DeLanda, M ( 2006) A New Philosophy of Society: Assemblage Theory and Social Complexity. London: Continuum.

Dourish, P, Bell, G ( 2007) The infrastructure of experience and the experience of infrastructure: Meaning and structure in everyday encounters with space. Environment and Planning B: Planning and Design 34(3): 414– 430., Doyer, H ( 1916) Ene Rijks-Electriciteitsvoorziening van Nederland. Delft: Waltman. Dyson, K, Humphreys, P ( 1988) Broadcasting and New Media Policies in Western Europe: A Comparative Study.

London: Routledge., Elias, N ( 2000[1939]) The Civilising Process: Pyschogenetic and Sociogenetic Investigations. Oxford: Blackwell. Foucault, M ( 1991) Questions of method.

In: Burchell, G. (eds) The Foucault Effect: Studies in Governmentality. Chicago: University of Chicago Press, 73– 86. Foucault, M ( 2001) The subject and power.

In: The Essential Works 1954–1984, Vol. London: Allen Lane. Gellner, E ( 1983) Nations and Nationalism. Ithaca, NY: Cornell University Press. Hannah, L ( 1977) A pioneer of public enterprise: The Central Electricity Board and the National Grid, 1927–1940. In: Supple, B (ed.) Essays in British History.

Oxford: Clarendon Press. Highmore, B ( 2001) Everyday Life and Cultural Theory. Environment Raven 7th Edition Pdf here.

London: Routledge. Hughes, TP ( 1983) Networks of Power: Electrification in Western Society, 1880–1930. Baltimore, MD: Johns Hopkins University Press. IEC ( 2014) World Plugs: Plugs and Sockets, International Standardization of Electrical Plugs and Sockets for Domestic Use.

Available at: ( accessed 21 June 2014). IECEE ( 1963[1957]) Publication 83, Standard for Plugs and Socket-Outlets for Domestic and Similar Purposes, 2nd edn. Geneva: IECEE CEE-7. Johnson, R ( 1993) Towards a cultural theory of the nation. In: Galema, B.

(eds) Images of the Nation: Different Meanings of Dutchness 1970–1940. London: Rodopi BV Editions, 161– 177. Jonnes, J ( 2004) Empires of Light: Edison, Tesla and Westinghouse and the Race to Electrify the World. London: Random House. Kuipers, G ( 2011) Her Majesty’s bicycle: On national habitus and sociological comparison. Figurations, special supplement no. 34, January: 1– 15.

Larkin, B ( 2008) Signal and Noise: Media, Infrastructure, and Urban Culture in Nigeria. Durham, NC: Duke University Press., Latour, B ( 2007) Reassembling the Social. Oxford: Oxford University Press. Lesage, D ( 2008) How to become Dutch. Afterall: A Journal of Art, Context, and Enquiry 18, Summer: 16– 26., Mellanby, J ( 1957) The History of Electrical Wiring. London: Macdonald.

Ministry of Works (MoW, 1944) Post War Building Study 11: Electrical Installations (Report of the Electrical Installations Committee). London: HMSO. Mullins, M ( 2006) The origin of the BS1363 plug and socket outlet system. Wiring Matters, Spring: 6– 8.

Schroeder, F ( 1986) More ‘small things forgotten’: Domestic electrical plugs and receptacles. Technology and Culture 27(3): 525– 543., Schwedt, G ( 2013) Experimente Rund Um Die Kunststoffe Des Alltags. Frankfurt: Wiley., Sinclair, B ( 1985) The First World Power Conference, 1924. Scientia Canadensis: Canadian Journal of the History of Science, Technology and Medicine/Scientia Canadensis: revue canadienne d’histoire des sciences, des techniques et de la medicine 9(2): 165– 172., Starr, L ( 1999) The ethnography of infrastructure. American Behavioral Scientist 43(3), November: 377– 391., Taylor, P ( 1994) The state as container: Territoriality in the modern world-system. Progress in Human Geography 18(2): 151– 162., The Times ( 1924) 3 July: 19.

Van der Vleuten, E ( 2009) Large Technical Systems. In: Berg Olsen, JK. (eds) A Companion to the Philosophy of Technology. London: Blackwell, 218– 222., Van der Vleuten, E ( 2010) Networked nation: Infrastructure integration of the Netherlands. In: Schot, J.

(eds) Technology and the Making of the Netherlands: The Age of Contested Modernization, 1890–1970. Eindhoven: MIT Press. VDEN (Vereeniging van Directeuren van Electriciteitsbedrijven, 1926) De ontwikkeling van de electriciteitsvoorziening van Nederland tot het jaar 1925; gedenkboek uitgegeven naar aanleiding van het 10-jarig bestaan van de vereeniging van directeuren van electriciteitsbedrijven in Nederland. Amsterdam: Van Kampen & Zoon. Verstegen, J ( 1986) Electric appliances.

In: Industry & Design in the Netherlands 1850–1950. Amsterdam: Stedelijk Museum Amsterdam, 283– 297. Weber, M ( 1978) Economy and Society, Vol. Berkeley: University of California Press.

Women’s Institute ( 1992) Going Electric. Guildford: Countryside Books, 69– 71. Available at: ( accessed 12 October 2012).